Main Website
Staircase Pressurization
Loading…
Project Information
Project Name
*
Consultant
*
Designer
*
Email
*
Ref
*
Date
System Definition
System Class
*
B
E
System Used VFD
*
No
Yes
System Type
Staircase
Staircase with Lobby and Lift
Number of levels
Staircase length (m)
Staircase width (m)
Staircase height (m)
Airflow Criterion (m/s)
Exit Level
Pressure difference criterion – Closed doors (Pa)
Boundary Conditions for Staircase
Single leaf doors – Open into the staircase
Single leaf doors – Open outwards from the staircase
Double leaf doors
Pivoted, no weather stripping (m2 per m length)
Pivoted and weather stripped (m2 per m length)
Sliding (m2 per m length)
Exterior building walls (m2)
Internal and stair walls (m2)
Lift well walls (m2)
Leakage Area [AE] for Staircase (m2)
Airflow required to [Stair]
Airflow required to [Stair] +50%
Boundary Conditions for Lobby
Single leaf doors – Open into the staircase
Single leaf doors – Open outwards from the staircase
Double leaf doors
Pivoted, no weather stripping (m2 per m length)
Pivoted and weather stripped (m2 per m length)
Sliding (m2 per m length)
Exterior building walls (m2)
Internal and stair walls (m2)
Lift well walls (m2)
Leakage Area [AE] for Lobby (m2)
Airflow required to [Lobby]
Airflow required to [Lobby] +50%
Boundary Conditions for Lift
Exterior building walls (m2)
Internal and stair walls (m2)
Lift well walls (m2)
Top Vent
Leakage Area [AE] for Lift (m2)
Airflow required to [Lift]
Lift Shaft Walls
W1 (m)
W2 (m)
W3 (m)
High (m)
Leakage Area [AE] for Lift Shaft Walls (m2)
Airflow required to [Lift Shaft Walls]
Total Airflow Required Mode 1
Airflow required to [Mode 1]
Mode 3
Fire Fighting – Velocity Criterion
Open Lift Door (2m High x 1m Wide) Leakage Area
Airflow required to [Open Lift Door] (m3/s)
Lift Top Vents
Airflow required to [Lift Top Vents]
Total Airflow required to [Lift Shaft]
Door size fire floor (m2)
Airflow to fire floor
Open exit door size (m2)
Airflow through open exit door
Summary
Fan Duty Required @ 50 Pa + System Resistance
Area Of Pressure Relief Staircase
Area Of Air/Smoke Relief Vent
Door size fire floor (m2)
Airflow to fire floor
Open exit door size (m2)
Airflow through open exit door
Summary
Fan Duty Required @ 50 Pa + System Resistance
Area Of Pressure Relief Staircase
Area Of Air/Smoke Relief Vent
System Type
Staircase
Staircase with Lobby
Staircase with Lobby and Lift
Number of levels
Staircase length (m)
Staircase width (m)
Staircase height (m)
Airflow Criterion (m/s)
Exit Level
Pressure difference criterion – Closed doors (Pa)
Boundary Conditions for Staircase
Single leaf doors – Open into the staircase
Single leaf doors – Open outwards from the staircase
Double leaf doors
Pivoted, no weather stripping (m2 per m length)
Pivoted and weather stripped (m2 per m length)
Sliding (m2 per m length)
Exterior building walls (m2)
Internal and stair walls (m2)
Lift well walls (m2)
Leakage Area [AE] for Staircase (m2)
Airflow required to [Stair]
Airflow required to [Stair] +50%
Boundary Conditions for Lobby
Single leaf doors – Open into the staircase
Single leaf doors – Open outwards from the staircase
Double leaf doors
Pivoted, no weather stripping (m2 per m length)
Pivoted and weather stripped (m2 per m length)
Sliding (m2 per m length)
Exterior building walls (m2)
Internal and stair walls (m2)
Lift well walls (m2)
Leakage Area [AE] for Lobby (m2)
Airflow required to [Lobby]
Airflow required to [Lobby] +50%
Boundary Conditions for Lift
Exterior building walls (m2)
Internal and stair walls (m2)
Lift well walls (m2)
Top Vent
Leakage Area [AE] for Top Vent
Leakage Area [AE] for Lift (m2)
Airflow required to [Lift]
Airflow required to [Lift] +50%
Mode 1
Total Airflow Required Mode 1
Airflow required to [Mode 1]
Airflow required to [Mode 1] +50%
Mode 2
Mode 2 [Pressure Criterion]
Exit Door Size (m2)
Air Flow (m3/s)
Airflow through open accommodation doors assuming open accommodation area at
Less than 50 m2
100 m2
400 m2
900 m2
1600 m2
Air Flow (m3/s)
Airflow through two open accommodation doors assuming open accommodation area at
Air Flow (m3/s)
Airflow required to [Mode 2 Pressure Criterion] + [Mode 1]
Mode 2 [Velocity Criterion]
Fire Floor Door Size (m2)
Airflow through open fire floor door (m3/s)
Airflow through open exit door (m3/s)
Airflow through open accommodation door (m3/s)
Total airflow required in Mode 2 (m3/s)
Summary
Fan Duty Required @ 50 Pa + System Resistance
Airflow Stair
Airflow to Stair lift
Airflow to Lobby
Airflow to Lift
Area Of Pressure Relief Staircase Only
Area Of Pressure Relief Staircase with Lobby
Area Of Pressure Relief Staircase with Lobby and Lift
Area Of Air/Smoke Relief Vent
*
Required